- Ranges
- RED 1 standard series (60W
to 2.4kw)
This series comprises mainly a single phase power transformer and
a rectifier bridge of 4 silicon diodes. It is basically fed in 240
or 220 V 50 Hz. Other voltages on request.
- RED 3 standard series (500W
to 22kW)
This serie comprises mainly a three-phase power transformer and
a three-phase rectifier bridge of 6 silicon diodes. It is basically
fed either in 415 of 380 V - or in 240 or 220 V. 3 ph. 50 Hz (to
specify in the order). Other voltages on request.
- Special ranges
Other couplings and powers are available on request.
- Reference number
The main characteristics of our rectifiers will be found
easily under the reference code.
Ex. :110 RED 3 50
110 : nominal output voltage
RED : diode rectifier (bridge)
3 : three-phase (1=single-phase)
50 : nominal output current.

- Performances
- DC output voltage
The DC output voltage does not vary perceptibly more than the secondary
AC output voltage with regard to the primary AC input voltage of
the power transformer. The voltage drop of the diodes is nearly
independent of the output current. lt is about 2 V.
- Voltage ripple
RED 1 series (full wave single phase rectifier bridge). The rate
of RMS ripple is 48.5% of the average output voltage.
RED 3 sertes (full wave three phase rectifier bridge). The rate
of RMS ripple is in this case 4.2% of the average output voltage.
Note : The use of one or more
RC/LC filter cells reduces the natural ripple of chosen rectifier.
- Equipment
Our standard series RED 1 and RED 3 mounted and wired
on a base-board, are foreseen to be incorporated in a more complex equipment
The standard equipment is transformer with separate windings protected
by input fuses, silicon diode rectifier, their quick acting fuses, overvoltage
protection (if necessary).
- Options
- Standard series of rectifiers
on base-board
lnput circuit-breaker in place of input fuses! RC or LC filters (1
or 2 cells) we have to know the maximum value ot the accepted ripple/Autotransformer
in place of transformer with separate windings.
- Standard series in metal enclosure
Input switch/lnput contactor with push-buttons/Output ammeter and
voltmeter.
|
|
|
l (mm)
|
h (mm)
|
p (mm)
|
(Kg)
|
|
12 red 1
|
5
|
200
|
150
|
150
|
4
|
|
|
10
|
200
|
150
|
150
|
6
|
| |
20
|
350
|
180
|
175
|
10
|
| |
50
|
350
|
160
|
215
|
18
|
| |
100
|
450
|
250
|
250
|
28
|
|
24 red 1
|
5
|
200
|
150
|
150
|
6
|
| |
10
|
350
|
190
|
175
|
10
|
| |
20
|
350
|
180
|
215
|
13
|
| |
50
|
450
|
250
|
250
|
25
|
| |
100
|
450
|
400
|
250
|
50
|
|
48 red 1
|
5
|
350
|
180
|
175
|
10
|
| |
10
|
350
|
180
|
215
|
13
|
| |
20
|
400
|
200
|
250
|
25
|
| |
50
|
450
|
400
|
250
|
25
|
|
110 red 1
|
5
|
350
|
180
|
215
|
13
|
| |
10
|
400
|
200
|
250
|
25
|
| |
20
|
450
|
400
|
250
|
45
|
|
220 red 1
|
5
|
400
|
200
|
250
|
25
|
| |
10
|
450
|
400
|
250
|
45
|
|
12 red 3
|
50
|
500
|
350
|
160
|
25
|
| |
100
|
600
|
425
|
200
|
40
|
| |
200
|
600
|
425
|
225
|
55
|
|
24 red 3
|
20
|
500
|
350
|
140
|
17
|
| |
50
|
500
|
350
|
150
|
30
|
| |
100
|
600
|
425
|
200
|
50
|
| |
200
|
425
|
650
|
250
|
85
|
|
43 red 3
|
20
|
500
|
350
|
160
|
30
|
| |
50
|
600
|
425
|
225
|
50
|
| |
100
|
425
|
650
|
250
|
75
|
| |
200
|
425
|
750
|
275
|
105
|
|
110 red 3
|
20
|
600
|
425
|
200
|
50
|
| |
50
|
625
|
650
|
250
|
80
|
| |
100
|
425
|
750
|
275
|
105
|
| |
200
|
485
|
750
|
300
|
160
|
|
220 red 3
|
10
|
600
|
425
|
200
|
50
|
| |
20
|
425
|
650
|
250
|
75
|
| |
50
|
425
|
650
|
275
|
105
|
| |
100
|
485
|
750
|
300
|
150
|
|